| Part Reference Number |
141-0313 |
| Basic spec |
Multi-function inverter/charger 12 V / 3 kVA / 160 A |
| Weight (kg) |
34.0000 |
| Manufacturer |
Studer Innotec, Switzerland |
| Manufacturer's Web Site |
www.studer-inno.com |
| Device Type |
Multifunction inverter/charger with Smart-Boost |
| Dimensions |
500 mm x 230 mm x 300 mm (H x D x W) |
| Nominal Battery Voltage |
12 V |
| Input Voltage Range (DC) |
9.5 - 17 V |
| Power Continuous |
2500 VA |
| Power 30 min @ 25°C |
3000 VA |
| Power 5 sec @ 25°C |
7500 VA |
| Max. load |
Up to short circuit |
| Max. asymmetric load |
Up to Pcont. |
| Load detection (stand by) |
2 to 25 W |
| Cos Ø |
0.1 - 1 |
| Max. efficiency |
93% |
| Consumption: off / stand by / on |
1.7 W / 2.2 W / 14 W |
| Output Voltage |
230 V AC |
| Output frequency |
50 Hz (adjustable 45 - 65 Hz) +/- 0.05% (crystal controlled) |
| Harmonic distortion |
< 2% |
| Overload & short circuit protection |
Auto disconnect with 3 restart attempts |
| Overheat protection |
Warning before shut-off followed by auto restart |
| Charging current |
0 - 160 A (adjustable) |
| Input current balance adjustment |
1 - 50 A |
| Max. input voltage |
265 V AC |
| Input voltage threshold range |
150 V - 230 V AC |
| Input frequency |
45 - 65 Hz |
| Power factor correction |
Yes (EN 61000-3-2) |
| Absorption voltage |
Set at 14.4 V (range: 9.5 - 17 V) |
| Absorption ends by |
Duration: set at 2 h ( range: 0.25 - 10 h) Current: not set (range: 4 - 30 A) |
| Floating voltage |
Set at 13.6 V (range: 9.5 - 17 V) |
| Time to start reduced floating |
Not set (range: 0 - 32 days) |
| Reduced floating voltage |
Not set (range: 9.5 - 17 V) |
| Equalisation start |
If required: by charge cycles or calendar intervals |
| Equalisation voltage |
Not set (range: 9.5 - 17 V) |
| Equalisation timing |
Not set (range: 0 - 10 h after start) |
| Time to start periodic absorption |
Not set (range: 0 - 31 days after reduced floating) |
| Periodic absorption timing |
Not set (range: 0 - 10 h) |
| Periodic absorption voltage |
Not set (range: 9.5 - 17 V) |
| Temperature compensation |
Set at -5 (range: 0 to -8 mV/°C/Cell) BTS-01 required |
| Max. current on Transfer Relay |
50 A |
| Transfer time |
< 15 ms |
| Auxiliary relays (AUX 1 & AUX 2) |
16 A max. @ 230 V AC (NO, COMM and NC contacts) |
| Protection index |
IP 23 |
| Operating temp. range |
-20°C to 55°C |
| Cooling |
Forced (fans) above 55°C |
| Sound level |
< 40 dB(A): fans off < 45 dB(A): fans on |
| Warranty |
2 years |